Good Response to Conventional Heat Detectors Used in Factory Fire Alarms

Shenzhen Sconda Intelligent Technology Co., Ltd
  • Audited Supplier
  • 3 yrs

Contact Supplier

Product Highlights

  • Long Battery Life: 3-year battery lifetime with replaceable 6F22 alkaline battery.
  • High Sensitivity: Advanced photoelectric smoke detection with precise analog and digital circuits.
  • Low Power Consumption: Standby current <10uA and alarm current <70mA for energy efficiency.
  • Wide Interlink Range: RF868MHz free field interlink range exceeds 100 meters.
  • Durable Design: ABS material construction with a 10-year product lifetime.
  • Compact and Portable: Small size (90*90*50mm) and lightweight (130g) for easy installation.
  • Compliant Standard: Meets EN 14604:2005+AC:2008 standard for reliable performance.
  • Clear Alarm Signal: Sound and light alarm with sound level >85dB for effective warning.

Product Images of Good Response to Conventional Heat Detectors Used in Factory Fire Alarms

Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms pictures & photos
Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
  • Good Response to Conventional Heat Detectors Used in Factory Fire Alarms
    Good Response to Conventional Heat Detectors Used in Factory Fire Alarms

Find Similar Products

Product Description

Good response to conventional heat detectors used in factory fire alarms

Advanced Features:
  • Photoelectric smoke detection
  • Reliable performance and less nuisance alarms
  • Precise analog circuit and digital circuit
  • Low power consumption
  • Small size
  • Portable
  • Interlink range >100m (RF868MHz free field)
Product Description:
Supply Voltage: DC 9V (6F22 Alkaline Battery)
Batter Lifetime: 3-years Replaceable
Low Battery Voltage: <2.6V
Standby Current: <10uA
Alarm Current: <70mA
Standard: EN 14604:2005+AC:2008
Installation Positions: Ceiling/Wall Mounting (With Accessories)
Operating Temperature: 0ºC~50ºC
Relative Humidity: <95%RH (non-condensing)
Alarm Method: Sound, Light Alarm
Alarm Sound Level: >85dB
Sensors Type: Infrared Photoelectric
Sensor Lifetime: 10-years
Product Weight: 130g
Product Size: 90.0*90.0*50.0mm
Good Response to Conventional Heat Detectors Used in Factory Fire AlarmsGood Response to Conventional Heat Detectors Used in Factory Fire AlarmsGood Response to Conventional Heat Detectors Used in Factory Fire AlarmsGood Response to Conventional Heat Detectors Used in Factory Fire AlarmsGood Response to Conventional Heat Detectors Used in Factory Fire AlarmsGood Response to Conventional Heat Detectors Used in Factory Fire Alarms

About the Supplier

Watch Video
Watch Video
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd
Shenzhen Sconda Intelligent Technology Co., Ltd

About Our Factory & Business Background

Address
Building #7, Chuangye Industrial Zone, Shapuwei Community, Songgang Street, Shenzhen, Guangdong, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Smoke Detector, Smart Wireless Smoke Co Gas Alarm, Gas Leak Detector, Carbon Monoxide Detector, Gas Analyzer Gas Monitors, Fire Detection & Fire Alarm Control, CO2 Detector, Pm2.5/10 Air Quality Monitors

Our Industry Experience & Global Business Record

Export Year
2018-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the battery life of the smoke detector?
The battery lifetime is 3 years, using a replaceable 6F22 alkaline battery.
What detection technology does it use?
It uses advanced photoelectric smoke detection with precise analog and digital circuits.
What is the interlink range for this device?
The interlink range is greater than 100 meters in a free field using RF868MHz.
What standards does the product comply with?
The product complies with the EN 14604:2005+AC:2008 standard.
What is the expected lifetime of the product?
The product has a lifetime of 10 years.
What are the power supply requirements?
It requires DC 9V power, specifically a 6F22 alkaline battery.
What is the alarm sound level?
The alarm sound level is greater than 85dB.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now